Step:1 Validate network interface on data mover
server_ifconfig server_2 -all
Step:2 Create and mount a file system called iSCSI
nas_fs -n iscsi -c size=100G pool=clar_r5_performance
server_mount server_2 iscsi /iscsi
Step:3 Create the celerra iSCSI target
server_iscsi server_2 -target -alias target -create 1000:np=172.12.32.189
Step:4 List iSCSI target
server_iscsi server_2 -target -list
Step:5 Create 2 iSCSI LUNs
server_iscsi server_2 -lun -number 1 -create target -size 1000 -fs iscsi
server_iscsi server_2 -lun -number 2 -create target -size 1000 -fs iscsi
#Size in MB
Step:6 List LUNs
server_iscsi server_2 -lun -list
Step:7 List all LUNs on target
server_iscsi server_2 -lun -info -all -target target
Step:8 Configure LUN mask
server_iscsi server_2 -mask -set target -initiator <fqdn> -grant 1-2
#Replace <fqdn> with the iscsi initiator
Step:9 Start iSCSI service
server_iscsi server_2 -service -start
Done!